Vertical furnace for fire resistance testing of building structures

Purpose of equipment
The vertical furnace is intended for testing of fire resistance of vertical structures. It allows fire loading according to EN 1363-1, EN 1363-2 or freely entered fire load up to 1200°C. The furnace is modular, consisting of pieces measuring 2 m × 2 m. The size of the sample opening is 4 m × 4 m, it contains 8 burners with a power of 1 MW each. Hydraulic cylinders enable measurements of the fire resistance of loaded structures up to 180 t.
Access of equipment
Responsible for equipment: PhD Nataša Knez
Access is possible in agreement with the person responsible for the equipment and only under the supervision of one of the qualified operators
ARIS research and infrastructure programmes (2) Legend
no. Code Title Period Head No. of publicationsNo. of publications
1.  P2-0273  Bulding structures and materials  1/1/2019 - 12/31/2027  PhD Andraž Legat  9,198 
2.  I0-0032  Preizkušanje materialov in konstrukcij (Slovene)  1/1/2015 - 12/31/2021  PhD Uroš Bohinc  6,642 